Quick Search:       Advanced Search
Chen Liyi. 1988. Polarographic determination of orthophosphate in seawater. Acta Oceanologica Sinica, (1):68-73
Polarographic determination of orthophosphate in seawater
Polarographic determination of orthophosphate in seawater
Received:August 10, 1986  Revised:June 09, 1987
DOI:
Key words:
中文关键词:  
基金项目:
Author NameAffiliation
Chen Liyi Department of Chemistry, Jishou University, Jishou, China 
Hits: 458
Download times: 358
Abstract:
      In the system HCl-Sb (Ⅲ)-ammonium molybdatc-acetone-butanone, PO43-, Sb (Ⅲ) and Mo (VI) form ternary heteropoly acid. This ternary heteropoly acid anion is adsorbed on the dropping mercury electrode and reduced quickly into heteropoly blue. The process of electrochemical reaction will produce a sensitive polarographic wave with peak potential -0.42V (vs S.C.E.). The detection limit is 6×10-8 mol/l. Variable coefficients are 10% and 3% for 0.1 μmol/l and 1 μmol/l respectively.
This method is sensitive, accurate and extremely rapid for analysis of seawater.
中文摘要:
      In the system HCl-Sb (Ⅲ)-ammonium molybdatc-acetone-butanone, PO43-, Sb (Ⅲ) and Mo (VI) form ternary heteropoly acid. This ternary heteropoly acid anion is adsorbed on the dropping mercury electrode and reduced quickly into heteropoly blue. The process of electrochemical reaction will produce a sensitive polarographic wave with peak potential -0.42V (vs S.C.E.). The detection limit is 6×10-8 mol/l. Variable coefficients are 10% and 3% for 0.1 μmol/l and 1 μmol/l respectively.
This method is sensitive, accurate and extremely rapid for analysis of seawater.
HTML View Full Text   View/Add Comment  Download reader
Close