LUO YINGHUA. 1984. DETERMINATION OF TRACE SILVER IN SEAWATER BY DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY METHOD WITH GLASSY CARBON-GOLD MEMBRANE ELECTRODE IN THE CASE OF LAMINAR FLOW. Acta Oceanologica Sinica, (4):517-526
DETERMINATION OF TRACE SILVER IN SEAWATER BY DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY METHOD WITH GLASSY CARBON-GOLD MEMBRANE ELECTRODE IN THE CASE OF LAMINAR FLOW
DETERMINATION OF TRACE SILVER IN SEAWATER BY DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY METHOD WITH GLASSY CARBON-GOLD MEMBRANE ELECTRODE IN THE CASE OF LAMINAR FLOW
Received:December 25, 1982  Revised:September 06, 1983
DOI:
Key words:
中文关键词:  
基金项目:
Author NameAffiliation
LUO YINGHUA Department of Chemistry, Xiamen University, Xiamen 
Hits: 780
Download times: 608
Abstract:
      This paper presents a new method to determine trace silver in seawater, the Differential pulse Anodic Stripping Voltammetry Method with Glassy Carbon-Gold Membrane Electrode in the Case of Laminar Flow, together with the description of its electrode structure, its principles and experimental conditions.Experimental results show that the reproducibility of glassy carbon electrode has been improved and the sensibility of determination of trace silver increased by combining the glassy carbon-gold membrane electrode with differential pulse stripping method in the case of laminar flow.
Determination could be conducted in non-preenriched natural seawater sample with an addition of HNO3 to 0.005 M and adistinct differential pulse anodic stripping peak be revealed.Sensibility is 2×10-10M, standard deviation (in six repeated tests) is ±2%, and recovery rate is 85-96%.Satisfactory results have been obtained in the determination of samples from the Xiamen Harbor and the high seas.
中文摘要:
      This paper presents a new method to determine trace silver in seawater, the Differential pulse Anodic Stripping Voltammetry Method with Glassy Carbon-Gold Membrane Electrode in the Case of Laminar Flow, together with the description of its electrode structure, its principles and experimental conditions.Experimental results show that the reproducibility of glassy carbon electrode has been improved and the sensibility of determination of trace silver increased by combining the glassy carbon-gold membrane electrode with differential pulse stripping method in the case of laminar flow.
Determination could be conducted in non-preenriched natural seawater sample with an addition of HNO3 to 0.005 M and adistinct differential pulse anodic stripping peak be revealed.Sensibility is 2×10-10M, standard deviation (in six repeated tests) is ±2%, and recovery rate is 85-96%.Satisfactory results have been obtained in the determination of samples from the Xiamen Harbor and the high seas.