设为首页 | 加入收藏
ZHANG Xiao,YE Ying,KAN Yating,HUANG Yuanfeng,JIA Jianjun,ZHAO Yue,CHEN Chen-Tung Arthur,QIN Huawei.A new electroplated Ir/Ir(OH)x pH electrode and its application in the coastal areas of Newport Harbor, California[J].Acta Oceanologica Sinica,2017,36(5):99-104
一种新型电镀法制备的Ir/Ir(OH)x pH电极及其在加州纽波特港海域的应用研究
A new electroplated Ir/Ir(OH)x pH electrode and its application in the coastal areas of Newport Harbor, California
投稿时间:2016-03-07  
DOI:10.1007/s13131-017-1064-5
中文关键词:  Ir/Ir(OH)x电极  pH值  电镀  加州纽波特港
英文关键词:Ir/Ir(OH)(OH)x electrode  pH value  electroplating  Newport Harbor  California
基金项目:The Key Laboratory Project of State Oceanic Administration for Marine Ecosystem and Biogeochemistry of China under contract No. 529101-X21601; the Foundation from Wendy Schmidt Ocean Health XPRIZE and the Southern California Coastal Water Research Project.
作者单位E-mail
张潇 浙江大学海洋学院, 舟山, 316021  
叶瑛 浙江大学海洋学院, 舟山, 316021  
阚雅婷 浙江大学海洋学院, 舟山, 316021  
黄元凤 浙江大学海洋学院, 舟山, 316021  
贾健君 浙江大学海洋学院, 舟山, 316021  
赵玥 浙江大学海洋学院, 舟山, 316021  
陈镇东 浙江大学海洋学院, 舟山, 316021
台湾中山大学海洋科学系, 高雄, 80204 
 
秦华伟 杭州电子科技大学机械工程学院, 杭州, 310018 qinhw@hdu.edu.cn 
摘要点击次数: 1887
全文下载次数: 1715
中文摘要:
      大气中CO2含量逐年上升,海洋酸化已经成为一个世界性难题。它对生态环境及人类的发展都产生着不可忽视的影响。因此,我们需要一个高精度传感器来监测海水pH值。本研究中传感器使用Ir/Ir(OH)x电极,制备时以直径为0.25mm的铱丝为基材,在室温条件下通过电化学法在其上原位合成Ir(OH)x膜。SEM图像显示铱丝表面包覆有纳米级颗粒的膜。该电极具有良好的能斯特斜率,并具有响应快速、稳定性与重现性好、寿命长的优点。将四支该方法制备的pH电极与一支参比电极集成于自制化学传感器,在加州纽波特港进行海试作业。结果显示,该传感器测得海水pH值与Sea-Bird 911 plus CTD测得数据十分接近,且在传感器下投和上拉过程中,数据吻合度更高。因此,自制海洋酸化传感器具有更高的精度和准确度。
英文摘要:
      Resulting from the rising levels of atmospheric carbon, ocean acidification has become a global problem. It has significant impacts on the development, survival, growth and physiology of marine organisms. Therefore, a high-precision sensor is urgently needed to measure the pH of sea-water. Iridium wire with a diameter of 0.25 mm is used as the substrate, and an Ir/Ir(OH)x pH electrode is prepared by a one-step electrochemical method in a LiOH solution at the room temperature. A scanning electron microscope (SEM) observation reveals that it is coated with nanoscale particles. In laboratory tests, the electrode exhibits a very promising pH response, with an ideal Nernst slope (56.14-59.52), fast response, good stability and long life-span in tested pH buffer solutions. For a sea trial, four pH electrodes and one Ag/AgCl reference electrode are integrated with a self-made chemical sensor, and a profile detection of nearly 70 m is implemented near Newport Harbor, California on August 3, 2015. The results reflect that the pH value measured by the sensor is very close to the data given by Sea-Bird 911 plus CTD, with a difference value ranging from 0.000 075 to 0.064 719. And the sensor shows a better data matching degree in 0-40 m water depth. In addition, the high precision and accuracy of the sensor make it possible to use in the ocean observation field.
查看全文   查看/发表评论  下载PDF阅读器