设为首页 | 加入收藏
ZHAO Yili,ZHU Jianhua,LIN Mingsen,CHEN Chuntao,HUANG Xiaoqi,WANG He,ZHANG Youguang,PENG Hailong.Assessment of the initial sea surface temperature product of the scanning microwave radiometer aboard on HY-2 satellite[J].Acta Oceanologica Sinica,2014,33(1):109-113
Assessment of the initial sea surface temperature product of the scanning microwave radiometer aboard on HY-2 satellite
Assessment of the initial sea surface temperature product of the scanning microwave radiometer aboard on HY-2 satellite
投稿时间:2012-08-26  修订日期:2013-01-18
DOI:10.1007/s13131-014-0402-0
中文关键词:  validation  sea surface temperature  HY-2 satellite  microwave radiometer
英文关键词:validation  sea surface temperature  HY-2 satellite  microwave radiometer
基金项目:The Marine Public Welfare Project of China under contract No. 201105032; the National High-Tech Project of China under contract No. 2008AA09A403; the fund of State Administration for Science, Technology and Industry for National Defense.
作者单位E-mail
ZHAO Yili National Ocean Technology Center, State Oceanic Administration, Tianjin 300111, China  
ZHU Jianhua National Ocean Technology Center, State Oceanic Administration, Tianjin 300111, China besmile@263.net 
LIN Mingsen National Satellite Ocean Application Service, State Oceanic Administration, Beijing 100081, China  
CHEN Chuntao National Ocean Technology Center, State Oceanic Administration, Tianjin 300111, China  
HUANG Xiaoqi National Ocean Technology Center, State Oceanic Administration, Tianjin 300111, China  
WANG He National Ocean Technology Center, State Oceanic Administration, Tianjin 300111, China  
ZHANG Youguang National Satellite Ocean Application Service, State Oceanic Administration, Beijing 100081, China  
PENG Hailong National Satellite Ocean Application Service, State Oceanic Administration, Beijing 100081, China  
摘要点击次数: 2016
全文下载次数: 2093
中文摘要:
      HY-2 satellite is the first satellite for dynamic environmental parameters measurement of China, which was launched on 16th August 2011. A scanning microwave radiometer (RM) is carried for sea surface temperature (SST), sea surface wind speed, columnar water vapor and columnar cloud liquid water detection. In this paper, the initial SST product of RM was validated with in-situ data of National Data of Buoy Center (NDBC)mooring and Argo buoy. The validation results indicate the accuracy of RMSST is better than 1.7℃. The comparison of RM SST and WindSat SST shows the former is warmer than the latter at high sea surface wind speed and the difference between these SSTs is depend on the sea surface wind speed. Then, the relationship between the errors of RM SST and sea surface wind speed was analyzed using NDBC mooring measurements. Based on the results of assessment and errors analysis, the suggestions of taking account of the affection of sea surface wind speed and using sea surface wind speed and direction derived from the microwave scatteromter aboard on HY-2 for SST product calibration were given for retrieval algorithm improvement.
英文摘要:
      HY-2 satellite is the first satellite for dynamic environmental parameters measurement of China, which was launched on 16th August 2011. A scanning microwave radiometer (RM) is carried for sea surface temperature (SST), sea surface wind speed, columnar water vapor and columnar cloud liquid water detection. In this paper, the initial SST product of RM was validated with in-situ data of National Data of Buoy Center (NDBC)mooring and Argo buoy. The validation results indicate the accuracy of RMSST is better than 1.7℃. The comparison of RM SST and WindSat SST shows the former is warmer than the latter at high sea surface wind speed and the difference between these SSTs is depend on the sea surface wind speed. Then, the relationship between the errors of RM SST and sea surface wind speed was analyzed using NDBC mooring measurements. Based on the results of assessment and errors analysis, the suggestions of taking account of the affection of sea surface wind speed and using sea surface wind speed and direction derived from the microwave scatteromter aboard on HY-2 for SST product calibration were given for retrieval algorithm improvement.
查看全文   查看/发表评论  下载PDF阅读器
关闭