设为首页 | 加入收藏
Guo Jinwen,L. Patterson,A. Amorelli,D. Condanni,B. Bazzoni.Experience on offshore cathodic protection retrofitting in the northern South China Sea[J].Acta Oceanologica Sinica,2003,(4):679-688
Experience on offshore cathodic protection retrofitting in the northern South China Sea
Experience on offshore cathodic protection retrofitting in the northern South China Sea
投稿时间:2003-06-18  修订日期:2003-08-12
DOI:
中文关键词:  Cathodic protection  retrofitting  offshore  the South China Sea
英文关键词:Cathodic protection  retrofitting  offshore  the South China Sea
基金项目:
作者单位
Guo Jinwen CACT Operators Group, Shenzhen 518069, China 
L. Patterson CACT Operators Group, Shenzhen 518069, China 
A. Amorelli ENI S. P. A. -Exploration & Production Division, Milan 20097, Italy 
D. Condanni ENI S. P. A. -Exploration & Production Division, Milan 20097, Italy 
B. Bazzoni ENI S. P. A. -Exploration & Production Division, Milan 20097, Italy 
摘要点击次数: 956
全文下载次数: 623
中文摘要:
      Platforms Ⅰ and Ⅱ are steel structures located in offshore areas southeast of the Zhujiang(Pearl) River Delta,the northern South China Sea,in about 110 m water depth.The jackets,with aluminum sacrificial anodes for cathodic protection(CP) of the immersed zone,were launched in March 1995.In May 1996 a CP survey showed that,after almost one year of service,a low polarization level had been achieved and some extended unprotected zones existed,mainly in the deepest part of the Platform Ⅱ.Further to this,a joint activity was decided in order to assess the need of a possible retrofitting of the CP systems.The results of the activity carried out are dealt with,including technical and economical comparisons amongst several retrofitting options,both with sacrificial anodes and with impressed current systems.The adopted solution is illustrated and data are reported on the level of protection presently achieved.
英文摘要:
      Platforms Ⅰ and Ⅱ are steel structures located in offshore areas southeast of the Zhujiang(Pearl) River Delta,the northern South China Sea,in about 110 m water depth.The jackets,with aluminum sacrificial anodes for cathodic protection(CP) of the immersed zone,were launched in March 1995.In May 1996 a CP survey showed that,after almost one year of service,a low polarization level had been achieved and some extended unprotected zones existed,mainly in the deepest part of the Platform Ⅱ.Further to this,a joint activity was decided in order to assess the need of a possible retrofitting of the CP systems.The results of the activity carried out are dealt with,including technical and economical comparisons amongst several retrofitting options,both with sacrificial anodes and with impressed current systems.The adopted solution is illustrated and data are reported on the level of protection presently achieved.