设为首页 | 加入收藏
MING XIUREN,HU QINXIAN,ZHU BIYING,LIU ZILIN,YANG WANLUN.A MICRO-FLUORESCENT METHOD FOR THE DE TERMINATION OF FREE AMINO ACIDS IN SEA-WATER AND THE DISTRIBUTION OF TOTAL FREE AMINO ACIDS[J].Acta Oceanologica Sinica,1985,(1):121-130
A MICRO-FLUORESCENT METHOD FOR THE DE TERMINATION OF FREE AMINO ACIDS IN SEA-WATER AND THE DISTRIBUTION OF TOTAL FREE AMINO ACIDS
A MICRO-FLUORESCENT METHOD FOR THE DE TERMINATION OF FREE AMINO ACIDS IN SEA-WATER AND THE DISTRIBUTION OF TOTAL FREE AMINO ACIDS
投稿时间:1983-11-29  修订日期:1984-01-30
DOI:
中文关键词:  
英文关键词:
基金项目:
作者单位
宁修仁 Second Institute of Oceanography, National Bureau of Oceanography, Hangzhou 
胡钦贤 Second Institute of Oceanography, National Bureau of Oceanography, Hangzhou 
朱碧英 Second Institute of Oceanography, National Bureau of Oceanography, Hangzhou 
刘子琳 Second Institute of Oceanography, National Bureau of Oceanography, Hangzhou 
杨万伦 Zhejiang Institute of Provisions Science, Hangzhou 
摘要点击次数: 832
全文下载次数: 559
中文摘要:
      O-phthaldialdehyde is used for the determination of free amino acid in seawater by measuring the fluorescence produced by its reaction with the a-amino group of amino acids. This method is so sensitive that as little as 1-10 nM of amino acids and less than 1 ml of seawater may be sufficient for one test.
This method is simple, rapid and accurate and a-amino acids contained in seawater can directly be determined without concentration and extraction. It is free from the interference of large content of inorganic salts and other nitrogenous compounds in seawater.
A hundred and fifty-two samples collected at 24 stations in offshore of Zhejiang have been analyzed. The results obtained show that the range of concentration of the total free amino acid is 0.37-4.70 μM. The values are high near shore and low offshore.
英文摘要:
      O-phthaldialdehyde is used for the determination of free amino acid in seawater by measuring the fluorescence produced by its reaction with the a-amino group of amino acids. This method is so sensitive that as little as 1-10 nM of amino acids and less than 1 ml of seawater may be sufficient for one test.
This method is simple, rapid and accurate and a-amino acids contained in seawater can directly be determined without concentration and extraction. It is free from the interference of large content of inorganic salts and other nitrogenous compounds in seawater.
A hundred and fifty-two samples collected at 24 stations in offshore of Zhejiang have been analyzed. The results obtained show that the range of concentration of the total free amino acid is 0.37-4.70 μM. The values are high near shore and low offshore.
查看全文   查看/发表评论  下载PDF阅读器
关闭